USGS SHORT PERIOD TELEMETRY STATIONS BASED ON L. WALD DATASET

The following dataset described the telemetered stations of the USGS network that is part of SCSN. This data was migrated into our current station metadata system (SIS). We have included it here for reference.

Definition of terms:
Sensor: Sensor type
GC: Sensor sensitivity
FQ: Sensor frequency
DP: Sensor damping constant
VCO: Voltage control oscillator type
VHZ: VCO max frequency
VV: VCO max voltage
VGAI: Adjustment to amplifier gain factor
AT: Attenuation
DISC: Discriminator type
DV: Discriminator max volts
DHZ: Discriminator max frequency
STANDARD GAIN FACTORS FOR VCOS
VCOTYPEVCOFACT
CIT 91.5
J112X 127.87
J312D 93.6
J312DX 93.6
J412H 93.6
J412HX 93.6
J512 93.6
J512A 93.6
J512AX 93.6
J512B 93.6
J512M 93.6
J512MX 93.6
J512X 93.6
KMI 90

STATCOTYPEFQDPGCVCOVHZVVVGAIATDISCDVDHZGAIN
    1 2   3 4   5         8   9
234 789 01234567890 234 67890 7890 2345678 90123 6789 12345 89 1234 7890 234 9012345
ABL VHZ L4 1 .8 1 J512M 105 4.05 0 18 J120 2.2 125 2252355
ARG VHZ L4 1 .8 1 KMI 125 2.5 24 48 J120 2.2 125 1438377
ARV VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
BAC VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.2 125 2252355
BAC VLE L4 1 .8 1 J512X 105 4.05 -24 24 J120 2.2 125 71226
BAC VLN L4 1 .8 1 J512X 105 4.05 -24 24 J120 2.2 125 71226
BAL VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
BAR VHZ L4 1 .8 1 J512A 105 4.05 0 30 J120 2.2 125 565766
BAT VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
BC3 VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.2 125 4494040
BCH VHZ L4 1 .8 1 J512M 105 4.05 0 12 J120 2.2 125 4494040
BLC VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
BLK VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
BMT VHZ L4 1 .8 1 J312D 105 4.05 0 6 J120 2.2 125 8966788
BNP VHZ   1 .8 1   0 0 0   J120 2.2 125 0
BR2 ASZ FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
BR2 ASN FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
BR2 ASE FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
BR2 VLZ L4 1 .8 1 J512MX 105 4.05 -24 36 J120 2.2 125 17891
BTL VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.2 125 2252355
CAL VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.2 125 2252355
CBK VHZ L4 1 .8 1 J512M 105 4.05 0 6 J120 2.2 125 8966788
CDY VHZ L4 1 .8 1 J512M 105 4.05 0 12 J120 2.2 125 4494040
CFL VHZ L4 1 .8 1 J512A 105 4.05 0 6 J120 2.5 125 189531
CFT VHZ L4 1 .8 1 J512A 105 4.05 0 30 J120 2.2 125 565766
CIS VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.2 125 2252355
CJV VHZ L4 1 .8 1 J412H 105 4.05 0 24 J120 2.2 125 1128852
CLC VHZ RANGER 1 .8 3.3 J512A 105 4.05 0 0 J120 2.2 125 9040609
CLC VLE L4 1 .8 1 J512M 105 4.05 0 8 J120 2.2 125 71226
CLC VLN L4 1 .8 1 J512A 105 4.05 0 8 J120 2.2 125 71226
CLI VHZ L4 1 .8 1 J512A 105 4.05 0 36 J120 2.2 125 283555
CLI VHE L4 1 .8 1 J512M 105 4.05 0 42 J120 2.2 125 142114
CLI VHN L4 1 .8 1 J412H 105 4.05 0 42 J120 2.2 125 142114
COA VHZ L4 1 .8 1 J412H 105 4.05 0 24 J120 2.2 125 1128852
COK VHZ L4 1 .8 1 J512M 105 4.05 0 30 J120 2.2 125 565766
CPE VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
CPM VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.2 125 4494040
CPM VLZ L4 1 .8 1 J412HX 105 4.05 -24 24 J120 2.2 125 71226
CRG VHZ L4 1 .8 1 J512M 105 4.05 0 18 J120 2.2 125 2252355
CSP VHZ RANGER 0 .7 0   0 0 0   J120 2.2 125 0
CTW VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
CTW VLZ L4 1 .8 1 J512MX 105 4.05 -24 24 J120 2.2 125 71226
DBM VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
DGR ASZ FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
DGR ASN FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
DGR ASE FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
DHB VLZ L1BHT 4.5 .7 0 OTS2 0 0 0 60 J120 2.2 125 0
DTP VHZ L4 1 .8 1 J512A 105 4.05 0 6 J120 2.2 125 8966788
EDW ASZ FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
EDW ASN FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
EDW ASE FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
EDW VLZ L4 1 .8 1 J412HX 105 4.05 -24 24 J120 2.2 125 71226
EL2 VHZ L4 1 .8 1 J512 105 4.05 0 24 J120 2.2 125 1128852
ELR VHZ L4 1 .8 1 J512M 105 4.05 0 36 J120 2.2 125 283555
ELS VHZ L4 1 .8 1 J512M 105 4.05 0 12 J120 2.2 125 4494040
EMS VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
ERP VHZ L4 1 .8 1 J512A 105 4.05 0 30 J120 2.2 125 565766
EW2 VHZ L4 1 .8 1 J412H 105 4.05 0 24 J120 2.2 125 1128852
EW2 VHE L4 1 .8 1 J512M 105 4.05 0 30 J120 2.2 125 565766
EW2 ASZ FBA 0 0 2.5   125 .63 0   J120 2.2 125 7152
EW2 ASN FBA 0 0 2.5   125 .63 0   J120 2.2 125 7152
EW2 ASE FBA 0 0 2.5   125 .63 0   J120 2.2 125 7152
EW2 VHN L4 1 .8 1 J512M 105 4.05 0 30 J120 2.2 125 565766
EW2 VLZ L4 1 .8 1 J412HX 105 4.05 -24 24 J120 2.2 125 71226
FLS VHZ L4 1 .8 1 J412H 105 4.05 0 24 J120 2.2 125 1128852
FLS ASZ FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
FLS ASN FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
FLS ASE FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
FMA VHZ L4 1 .9 2.9 DVEL 100 0 0 42 J120 2.2 125 0
FOX VHZ L4 1 .8 1 J412H 105 4.05 0 30 J120 2.2 125 565766
FRG VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.2 125 4494040
FRI VHZ   1 .8 1   0 0 0 24 J120 2.2 125 0
FRK VHZ L4 1 .8 1 J512M 105 4.05 0 18 J120 2.2 125 2252355
GAV VHZ L4 1 .8 1 J512M 105 4.05 0 30 J120 2.2 125 565766
GAV VLE L4 1 .8 1 J512MX 105 4.05 -24 24 J120 2.2 125 71226
GAV VLN L4 1 .8 1 J512AX 105 4.05 -24 24 J120 2.2 125 71226
GAV VLZ L4 1 .8 1 J412HX 105 4.05 -24 24 J120 2.2 125 71226
GFP VLZ L4 1 .9 2.9 KIN 0 0 0 36 J120 2.2 125 0
GRP VHZ L4 1 .8 1 J412H 105 4.05 0 6 J120 2.2 125 8966788
GSA AFZ FBA 0 0 2.5 GSP 0 0 .5 24   0 0 0
GSA AFN FBA 0 0 2.5 GSP 0 0 .5 24   0 0 0
GSA AFE FBA 0 0 2.5 GSP 0 0 .5 24   0 0 0
GSA VLE L4 1 .8 1 J112X 1 1 -24 36   2.2 125 35678
GSA ASZ FBA 0 0 2.5 GSP 0 0 16 -6   0 0 0
GSA ASN FBA 0 0 2.5 GSP 0 0 16 -6   0 0 0
GSA ASE FBA 0 0 2.5 GSP 0 0 16 -6   0 0 0
GSA VLN L4 1 .8 1 J112X 1 1 -24 36   2.2 125 35678
GSA VLZ L4 1 .8 1 J112X 1 1 -24 36   2.2 125 35678
GSC VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
GTM VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
GVR VHZ L4 1 .8 1 J412H 105 4.05 0 42 J120 2.2 125 142114
GVR VLE L4 1 .8 1 J412HX 105 4.05 -24 30 J120 2.2 125 35697
GVR ASZ FBA 0 0 5   125 1.25 0 0 J120 2.2 125 7209
GVR ASN FBA 0 0 5   125 1.25 0 0 J120 2.2 125 7209
GVR ASE FBA 0 0 5   125 1.25 0 0 J120 2.2 125 7209
GVR VLN L4 1 .8 1 J412HX 105 4.05 -24 30 J120 2.2 125 35697
HAY VHZ L4 1 .7 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
HCM VHZ L4 1 .8 1 DVEL 0 0 0   J120 2.2 125 0
HMT VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.5 125 2559495
HMT VLE L4 1 .8 1 J512AX 105 4.05 -24 24 J120 2.5 125 80938
HMT VLN L4 1 .8 1 J512MX 105 4.05 -24 24 J120 2.5 125 80938
HOD VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
HOL VHZ L4 1 .8 1 J512B 105 4.05 0 12 J120 2.2 125 4494040
HYS VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
IKP VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
INS VHZ L4 1 .8 1 J512M 105 4.05 0 12 J120 2.2 125 4494040
IR2 VHZ RANGER 1 .7 3.3 J512A 125 4.05 0 18 J120 2.5 125 55157
IRS VHZ L4 1 .8 1 J512M 105 4.05 0 30 J120 2.2 125 565766
ISA VHZ RANGER 1 .8 3.3 CIT 115 3.2 0 2 J120 2.2 125 0
ISA VLE SIM TORS .8 .8 3.5 CIT 125 3.5 0 20 J120 2.2 125 0
ISA VLN SIM TORS .8 .8 3.5 CIT 125 3.5 0 20 J120 2.2 125 0
JFS VHZ L4 1 .8 1 J412H 105 4.05 0 18 J120 2.2 125 2252355
JNH VHZ L4 1 .8 1 J412H 105 4.05 0 18 J120 2.2 125 2252355
JUL VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.5 125 5106863
LAQ VHZ L4 1 .8 1 J512M 105 4.05 0 18 J120 2.2 125 2252355
LCL VHZ L22E 1 .7 2 J412H 0 2.2 0 42 J120 2.2 125 0
LCL VLE L22E 2 .7 0 DVEL 0 2.2 0 42 J120 2.2 125 0
LCL VLN L22E 2 .7 0 J412H 0 2.2 0 42 J120 2.2 125 0
LEO VHZ L4 1 .8 1 J412H 105 4.05 0 18 J120 2.2 125 2252355
LRL VHZ L4 1 .8 1 J512M 105 4.05 0 12 J120 2.2 125 4494040
LRL ASZ FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
LRL ASN FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
LRL ASE FBA 0 0 5   125 1.25 0   J120 2.2 124 7267
LRR VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
LTC VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
LUC VHZ L4 1 .8 1 J512A 105 4.05 0 36 J120 2.2 125 283555
MAR VHZ L4 1 .8 1 J512M 105 4.05 0 12 J120 2.2 125 4494040
MDA VHZ L4 1 .8 1 J312D 105 4.05 0 24 J120 2.2 125 1128852
MEC VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
MIR VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
MMI VHZ L4 0 0 0   0 0 0   J120 2.2 125 0
MTC VLZ L4 1 .8 1   0 0 0   J120 2.2 125 0
MTU VHZ L4 1 .8 1   0 0 0 24 J120 2.2 125 0
MWC VHZ RANGER 1 .8 3.3 J512A 105 4.05 0 18 J120 2.2 125 7432772
MWC ASZ FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
MWC ASN FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
MWC ASE FBA 0 0 5   125 2.5 0   J120 2.2 125 3604
NW2 VHZ L4 1 .8 1 J512M 105 4.05 0 42 J120 2.2 125 142114
OAK VHZ L4 1 .8 1 J512A 105 4.05 0 30 J120 2.2 125 565766
OAK VLE L4 1 .8 1 J512A 105 4.05 0 48 J120 2.2 125 71226
OAK VLN L4 1 .8 1 J512A 105 4.05 0 48 J120 2.2 125 71226
OLY VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
ORK VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
ORV VHZ BBENIOFF 0 0 0   0 0 0   J120 2.2 125 0
PAD VHZ L4 1 .8 1   0 0 0 24   0 0 0
PAS VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
PAS BLZ STRECK. 1 .8 1   0 0 0   J120 2.2 125 0
PAS BLN STRECK. 1 .8 1   0 0 0   J120 2.2 125 0
PAS BLE STRECK. 1 .8 1   0 0 0   J120 2.2 125 0
PAS LHE STRECK. 1 .8 1   0 0 0   J120 2.2 125 0
PAS LHN STRECK. 1 .8 1   0 0 0   J120 2.2 125 0
PAS LHZ STRECK. 1 .8 1   0 0 0   J120 2.2 125 0
PBI VHZ L4 1 .8 1   0 0 0   J120 2.2 125 0
PEC VHZ RANGER 0 .7 0   0 0 0   J120 2.2 125 0
PEM VHZ L4 1 .8 1 J412H 105 4.05 0 18 J120 2.2 125 2252355
PEM VLZ L4 1 .8 1 J412HX 105 4.05 -24 24 J120 2.2 125 71226
PHC VHZ L4 1 .8 1   0 0 0 24 J120 2.2 125 0
PKM VHZ L4 1 .8 1 J512M 105 4.05 0 12 J120 2.2 125 4494040
PLE VHZ L4 1 .8 1 J512M 105 4.05 0 30 J120 2.2 125 565766
PLS VHZ L4 1 .8 1 J512A 105 4.05 0 30 J120 2.2 125 565766
PLS VHE L4 1 .8 1 J412H 105 4.05 0 36 J120 2.2 125 283555
PLS ASZ FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
PLS ASN FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
PLS ASE FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
PLS VHN L4 1 .8 1 J412H 105 4.05 0 36 J120 2.2 125 283555
PLT VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.2 125 4494040
PMC VHZ L4 1 .8 1   0 0 0     0 0 0
PMC VLE L4 1 .8 1   0 0 0     0 0 0
PMC VLN L4 1 .8 1   0 0 0     0 0 0
PMC VLZ L4 1 .8 1   0 0 0 24   0 0 0
PMG VHZ L4 1 .8 1   0 0 0 24 J120 2.2 125 0
PNM VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.2 125 4494040
POB VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
PPB VHZ L4 1 .8 1   0 0 0 24 J120 2.2 125 0
PPR VHZ L4 1 .8 1   0 0 0 24 J120 2.2 125 0
PRI VHZ BENIOFF 1 0 .2   0 0 0 24 J120 2.2 125 0
PSH VHZ L4 1 .8 1   0 0 0 24 J120 2.2 125 0
PSM VHZ L4 1 .8 1   0 0 0 24 J120 2.2 125 0
PSP VHZ L4 1 .8 1 J412H 105 4.05 0 30 J120 2.2 125 565766
PTD VHZ L4 1 .8 1 J512A 105 4.05 0 36 J120 2.2 125 283555
PTQ VHZ L4 1 .8 1   0 0 0 24 J120 2.2 125 0
PYR VHZ RANGER 0 .7 0   0 0 0   J120 2.2 125 0
QAL VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
RAY VHZ L4 1 .8 1 J512B 105 4.05 0 12 J120 2.2 125 4494040
RAY VLZ L4 1 .8 1 J512B 105 4.05 0 48 J120 2.2 125 71226
RMM VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.2 125 2252355
RMM VLE L4 1 .8 1 J512AX 105 4.05 -24 24 J120 2.2 125 71226
RMM VLN L4 1 .8 1 J412HX 105 4.05 -24 24 J120 2.2 125 71226
RMM VLZ L4 1 .8 1 J412HX 105 4.05 -24 24 J120 2.2 125 71226
RMR VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.2 125 2252355
RUN VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
RVR VHZ L4 1 .8 1 J512A 105 4.05 0 30 J120 2.2 125 565766
RYS VHZ L4 1 .8 1 J512M 105 4.05 0 18 J120 2.2 125 2252355
SAD VHZ L4 1 .8 1 J412H 105 4.05 0 18 J120 2.2 125 2252355
SBB VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.2 125 2252355
SBI VHZ L4 1 .9 2.9 DVEL 0 0 0 18 J120 2.2 125 0
SBK VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
SBP ASZ FBA 0 0 5   125 1.25 0 0 J120 2.2 125 7209
SBP ASN FBA 0 0 5   125 1.25 0 0 J120 2.2 125 7209
SBP ASE FBA 0 0 5   125 1.25 0 0 J120 2.2 125 7209
SBP VLZ L4 1 .8 1 J312DX 105 4.05 -24 24 J120 2.2 125 71226
SC1 VHZ GUR1G 0 0 7.6 NONE 100 0 0   J120 2.2 125 0
SCC VHZ L4 1 .8 1 J312D 105 4.05 0 18 J120 2.2 125 2252355
SCD VHZ L4 1 .8 1 J312D 105 4.05 0 24 J120 2.2 125 1128852
SCI VHZ L4 1 .8 1 J412H 105 4.05 0 30 J120 2.2 125 565766
SCI VLE L4 1 .8 1 J412HX 105 4.05 -24 18 J120 2.2 125 142114
SCI VLN L4 1 .8 1 J412HX 105 4.05 -24 18 J120 2.2 125 142114
SCY VHZ L4 1 .8 1 J512A 125 4.05 0 30 J120 2.2 125 673531
SGL VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
SHH VHZ L4 1 .8 1 J412H 105 4.05 0 6 J120 2.2 125 8966788
SIL VHZ L4 1 .8 1 J512M 105 4.05 0 18 J120 2.2 125 2252355
SIL VLZ L4 1 .8 1 J412HX 105 4.05 -24 24 J120 2.2 125 71226
SIM VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
SIP VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
SIP VLE L4 1 .8 1 J512AX 105 4.05 -24 24 J120 2.2 125 71226
SIP VLN L4 1 .8 1 J512AX 105 4.05 -24 24 J120 2.2 125 71226
SKY VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.5 125 2559495
SLC VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
SLD VHZ L4 1 .8 1   0 0 0   J120 2.2 125 0
SLG VHZ L4 1 .8 1 J412H 105 4.05 0 18 J120 2.2 125 2252355
SLP VHZ L4 1 .8 1 J312D 105 4.05 0 24 J120 2.2 125 1128852
SME VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
SMF VHZ L4 1 .8 1 J512B 105 4.05 0 30 J120 2.2 125 565766
SMF VLE L4 1 .8 1 J512AX 105 4.05 -24 36 J120 2.2 125 17891
SMF ASZ FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
SMF ASN FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
SMF ASE FBA 0 0 5   125 1.25 0   J120 2.2 125 7209
SMF VLN L4 1 .8 1 J512AX 105 4.05 -24 36 J120 2.2 125 17891
SMF VLZ L4 1 .8 1 J512B 105 4.05 0 48 J120 2.2 125 71226
SND VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
SNR VHZ L4 1 .8 1 J512M 105 4.05 0 36 J120 2.2 125 283555
SNR VHE L4 1 .8 1 J412H 105 4.05 0 36 J120 2.2 125 283555
SRT VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
SS2 VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
SSC VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
SSC VHE L4 1 .8 1 J512A 105 4.05 0 36 J120 2.2 125 283555
SSC VHN L4 1 .8 1 J512A 105 4.05 0 36 J120 2.2 125 283555
SSN VHZ L4 1 .8 1 J412H 105 4.05 0 18 J120 2.2 125 2252355
STT VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
SU2 VHZ L4C 1 .8 1 J512A 125 4.05 0 30 J120 2.2 125 673531
SUN VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
SXT VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
SYP VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
TAB VHZ L4 1 .8 1 J412H 105 4.05 0 24 J120 2.2 125 1128852
TAB VLZ L4 1 .8 1 J512AX 105 4.05 -24 30 J120 2.2 125 35697
TCC VHZ L4 1 .8 1 J312D 105 4.05 0 36 J120 2.2 125 283555
TEJ VHZ L4 1 .8 1 J412H 105 4.05 0 24 J120 2.2 125 1128852
THC VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
TJR VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.2 125 4494040
TM2 VHZ L4 1 .8 1 J512A 105 4.05 0 30 J120 2.2 125 565766
TOW VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
TPC VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.2 125 4494040
TPO VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
TPR VHZ SS-1 1 0 0 OTS2 0 0 0 24 J120 2.2 125 0
VPD VHZ L4 1 .8 1 J512M 105 4.05 0 24 J120 2.2 125 1128852
VST VHZ RANGER 1 .8 3.3 J512A 105 4.05 0 36 J120 2.2 125 935731
VVD VHZ L4 1 .8 1 J512A 105 4.05 0 24 J120 2.2 125 1128852
WAS VHZ L4 1 .8 1 J312D 105 4.05 0 18 J120 2.2 125 2252355
WBM VHZ L4 1 .8 1 J312D 105 4.05 0 24 J120 2.2 125 1128852
WBS VHZ L4 1 .8 1 J412H 105 4.05 0 18 J120 2.2 125 2252355
WCH VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
WCS VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
WHF VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
WHV VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
WI2 VHZ L4 1 .8 1 J512M 105 4.05 0 36 J120 2.2 125 283555
WI2 VLE L4 1 .8 1 J512A 105 4.05 0 48 J120 2.2 125 71226
WIN VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.5 125 2559495
WIN VLE L4 1 .8 1 J512AX 105 4.05 -24 24 J120 2.5 125 80938
WIN VLN L4 1 .8 1 J512AX 105 4.05 -24 24 J120 2.5 125 80938
WJP VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
WLH VHZ L4 1 .8 1 J512M 105 4.05 0 18 J120 2.2 125 2252355
WMF VHZ L4 1 .8 1 J412H 105 4.05 0 6 J120 2.2 125 8966788
WMP VHZ L4 1 .8 1 J312D 105 4.05 0 24 J120 2.2 125 1128852
WMP ASZ FBA 0 0 5   0 0 0   J120 2.2 125 0
WMP ASN FBA 0 0 5   0 0 0   J120 2.2 125 0
WMP ASE FBA 0 0 5   0 0 0   J120 2.2 125 0
WNM VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
WOF VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.2 125 4494040
WOR VHZ L4 1 .8 1 J312D 105 4.05 0 18 J120 2.2 125 2252355
WRC VHZ L4 1 .8 1 J412H 105 4.05 0 6 J120 2.2 125 8966788
WRV VHZ L4 1 .8 1 J412H 105 4.05 0 12 J120 2.2 125 4494040
WS2 VHZ L4 1 .8 1 J512A 125 4.05 0 18 J120 2.2 125 2681375
WSH VHZ L4 1 .8 1 J312D 105 4.05 0 6 J120 2.2 125 8966788
WVP VHZ L4 1 .8 1 J512M 105 4.05 0 18 J120 2.2 125 2252355
WWP VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
XMS VHZ L4 1 .8 1 J312D 105 4.05 0 12 J120 2.2 125 4494040
XTL VHZ L4 1 .8 1 J512A 105 4.05 0 12 J120 2.5 125 5106863
YEG VHZ L4 1 .8 1 J312D 105 4.05 0 18 J120 2.2 125 2252355
YMD VHZ L4 1 .8 1 J512A 105 4.05 0 18 J120 2.2 125 2252355
YUH VHZ L4 1 .8 1 J512A 105 4.05 0 6 J120 2.2 125 8966788